Morse Code Translator
  1. Translator
  2. Baudot code translator

Baudot code translator (ITA2)

Translate English text to five-bit ITA2, or read the groups back as text. See the shift state and tape holes for every group, with the bit order stated explicitly.

This Baudot code translator uses International Telegraph Alphabet No. 2 (ITA2). It keeps the LETTERS and FIGURES shifts in the output, shows every group’s meaning, and draws its five data elements. ITA2’s five-unit table is defined in (ITU-T S.1, sections 2–4 and Table 1).

Translate text and ITA2

Everything you type stays in your browser; this tool sends no text over the network.

Enable JavaScript to convert your message. The example and complete reference below work without it.

How do I generate Baudot code from text?

Choose Text to ITA2, type a short message, and press Convert. Try HELLO 73 first. The result includes the shift groups you need to keep when copying. Open the trace to see the meaning of each group and the state before and after it.

This converter changes English lowercase letters to capitals. It accepts digits, ordinary spaces, carriage returns, line feeds, and the punctuation listed beside the input. It rejects an unsupported character with its position so you can choose a replacement yourself. It does not remove accents or silently discard symbols.

Start with a single word when checking a source. Once that works, add a number and compare where the trace changes to FIGURES. Use Copy result to keep the complete encoded stream, including its leading LTRS.

What do LETTERS and FIGURES mean?

The same group can have two meanings. Numeric 00001 means E in LETTERS and 3 in FIGURES. LTRS (11111) selects letters; FIGS (11011) selects figures. The latest shift determines the interpretation (S.1, Table 1 and section 4.4).

In this tool, encoding begins with LTRS, then inserts another shift whenever your message needs the other set. A space keeps the current state. For example, the digits in 73 73 remain in FIGURES across the space; adding an A afterward requires LTRS. Look for those separate rows rather than counting one code group per visible character.

A3A in ITA2, with numeric binary (elements 5→1)

11111 00011 11011 00001 11111 00011

Each group, including shifts; tape diagrams always show data elements 1→5
Numeric bits 5→1Tape elements 1→5MeaningState before → after
11111LTRS: select lettersletters → letters
00011Aletters → letters
11011FIGS: select figuresletters → figures
000013figures → figures
11111LTRS: select lettersfigures → letters
00011Aletters → letters

How do I translate Baudot code to English?

Choose ITA2 to text, match the bit order and code format to your source, then paste the groups. Spaces and line breaks may separate complete five-position groups. A continuous stream is also accepted if its length is a multiple of five. The converter rejects incomplete groups instead of padding them or guessing a missing bit.

If your input starts midway through a message, choose the initial decode state. For a lone numeric 00001, LETTERS gives E and FIGURES gives 3. A shift in the stream takes over from that setting. The status line warns when no leading shift was present, so you can distinguish an assumption from an explicit instruction.

Keep the shift trace open while checking a result. A run of unexpected punctuation may mean the input needed a different initial state. If nothing looks plausible, check the bit order before changing the message itself.

Which order do the five bits go in?

The standard numbers code elements 1 through 5 and sends element 1 first. It assigns 0 to no tape perforation and 1 to a perforation (S.1, section 3.2 and Table 1 note). This page offers both transmitted order 1→5 and numeric binary 5→1.

Here, element 1 has numeric weight 1, element 2 has weight 2, then 4, 8, and 16. Consequently A is numeric value 3, displayed as 00011 in numeric order and 11000 in transmitted order. Reversing the display changes the written group, while keeping the character and its numeric value the same.

The reference lists both orders. Its numeric values from 0 to 31 are our lookup convention; they are not the standard’s alphabetically arranged combination numbers. Select the order before decoding. Changing the setting clears the previous result and leaves your input available for review.

How do I read the tape holes?

For symbol output, choose ● hole and ○ no hole. You can copy that representation and paste it back with the same format and bit order selected. The trace always draws data elements 1→5, even when the text result uses numeric order.

Each diagram numbers the elements. A filled circle is 1; an outlined circle is 0. Its accessible label also gives the bits and the elements with holes. These are simplified data diagrams: they omit feed holes and do not establish which edge of a photographed tape you are viewing. Transcribe a known orientation before using the decoder.

What is the international ITA2 table?

The table follows S.1 and was cross-checked against the WMO’s reproduction. In FIGURES, Z’s position is + and V’s is = (WMO-No. 386, page 55). All five positions count, including zeros at either end.

International ITA2 reference: ITU-T S.1, Table 1. Numeric values are not the standard’s combination numbers.
Numeric valueBits 5→1Elements 1→5LETTERSFIGURES
00000000000All-space / nullAll-space / null
10000110000E3
20001001000Line feedLine feed
30001111000A-
40010000100SpaceSpace
50010110100S'
60011001100I8
70011111100U7
80100000010Carriage returnCarriage return
90100110010DWho are you? (answerback)
100101001010R4
110101111010JAudible signal
120110000110N,
130110110110FNational/private figure at F
140111001110C:
150111111110K(
161000000001T5
171000110001Z+
181001001001L)
191001111001W2
201010000101HNational/private figure at H
211010110101Y6
221011001101P0
231011111101Q1
241100000011O9
251100110011B?
261101001011GNational/private figure at G
271101111011FIGS: select figuresFIGS: select figures
281110000111M.
291110110111X/
301111001111V=
311111111111LTRS: select lettersLTRS: select letters

Why are some punctuation marks unavailable?

The FIGURES positions paired with F, G, and H have no universal assignment in S.1. National or private use needs its own agreement (S.1, section 4.2). This decoder preserves those groups as bracketed national/private labels instead of substituting US TTY symbols.

Likewise, WRU and the audible signal are control functions, rather than ordinary punctuation (WMO-No. 386, pages 54–56). The tool shows [WRU] and [BEL] without operating any device. It shows [NUL] for the all-zero group. Carriage return and line feed affect the text layout and have separate labeled trace rows. Bracketed labels describe received codes; typing those words into the encoder does not recreate the controls.

Baudot vs. Morse: can I send these bits?

ITA2 groups contain five data elements; Morse characters use short and long signals with defined spacing (S.1, section 3.1), (ITU-R M.1677-1, Annex 1). A five-bit ITA2 group is therefore not a Morse character.

You can make a two-step exercise by encoding A here, then sending the written digits 11111 00011 as Morse. The widget below does that. It plays Morse for the digit characters, including the group boundary as a word space. It does not reproduce a teleprinter’s electrical signal or serial framing.

A becomes ITA2 bit groups first; this widget sends their written 0 and 1 digits in Morse.

Compare the digit signals in the Morse code alphabet, or paste your groups into the Morse translator. For listening practice, use the guide to learning Morse by ear. Morse vs. binary explains the distinction further; the binary translator covers text bytes rather than ITA2 shifts.

What should I check before trusting a decode?

Confirm that your source actually uses this international ITA2 table. This page does not implement original Baudot ITA1, US TTY, national figure variants, extended lowercase procedures, audio recognition, or start/stop framing. A plausible word alone does not establish the source’s format.

Check the bit order, the starting state, and every group boundary. Compare a known character with the reference before decoding the rest. For long input, split it at a known shift and set the initial state for each part. The limits are 240 text characters or 800 groups, with an 8,000-character ceiling for pasted code. An error leaves no partial result to mistake for a complete message.

Sources

  1. Recommendation ITU-T S.1: International Telegraph Alphabet No. 2, sections 2–4 and Table 1. International Telecommunication Union, March 1993; checked 11 November 2026.
  2. Manual on the Global Telecommunication System, WMO-No. 386: Attachment II-1, Table 1/S.1, page 55. World Meteorological Organization; hosted by Mongolia’s meteorological service, 2023; checked 11 November 2026.
  3. Recommendation ITU-R M.1677-1, International Morse code. ITU Radiocommunication Sector, October 2009.